
Safe checkout
Secure payments
Fast dispatch
1–2 day handling
Free shipping
U.S. ground
Warranty & RMA
Support after delivery
BR1200GI - APC 720W / 1200VA 7Ah UPS Battery
- Line-Interactive
- 1.2 kVA 720 W
- Waveform: Sine
- 10 AC outlet(s)
- Sealed Lead Acid (VRLA)
- Black
Request a price for BR1200GI — we confirm current pricing and lead time within one business day.
Key specifications
See full specs ↓- UPS topology
- Line-Interactive
- Output power capacity
- 1.2 kVA
- Output power
- 720 W
- Waveform
- Sine
- Input operation voltage (min)
- 156 V
- Input operation voltage (max)
- 300 V
Product details
APC Back-UPS Pro. UPS topology: Line-Interactive, Output power capacity: 1.2 kVA, Output power: 720 W. AC outlet types: C13 coupler, Power plug: C14 coupler, AC outlets quantity: 10 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Battery capacity: 187 VAh, Typical backup time at full load: 5.4 min. Product colour: Black, Display type: LCD. Compliance certificates: RoHS, Certification: A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV, REACH, PEP, EOLI
Features
| UPS topology | Line-Interactive |
| Output power capacity | 1.2 kVA |
| Output power | 720 W |
| Waveform | Sine |
| Input operation voltage (min) | 156 V |
| Input operation voltage (max) | 300 V |
| Input frequency | 50/60 Hz |
| Output frequency regulation | 50/60 Hz |
| Automatic Voltage Regulation (AVR) | Yes |
| Surge energy rating | 441 J |
| Hold time (min) | 10 ms |
| Hold time (max) | 12 ms |
| Efficiency | 98.8% |
| Crest factor | 3:1 |
| Noise level | 45 dB |
| Surge protection | Yes |
| Surge protection features | Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone |
| Audible alarm(s) | Yes |
| Audible alarm modes | Low battery alarm, Overload alarm |
Ports & interfaces
| AC outlet types | C13 coupler |
| Power plug | C14 coupler |
| AC outlets quantity | 10 AC outlet(s) |
| Number of output IEC jumpers | 2 |
| USB port | Yes |
Battery
| Battery technology | Sealed Lead Acid (VRLA) |
| Battery capacity | 187 VAh |
| Typical backup time at full load | 5.4 min |
| Typical backup time at half load | 15.7 min |
| Battery life (max) | 5 year(s) |
| Battery recharge time | 8 h |
| Hot-swap battery | Yes |
| Automatic battery test | Yes |
| Cold start | Yes |
| Replacement battery cartridge | 1 |
Design
| Product colour | Black |
| Display type | LCD |
Operational conditions
| Operating temperature (T-T) | 0 - 40 °C |
| Storage temperature (T-T) | -15 - 45 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 9000 m |
| Non-operating altitude | 0 - 15000 m |
Certificates
| Compliance certificates | RoHS |
| Certification | A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV, REACH, PEP, EOLI |
Packaging content
| Cables included | Phone (RJ-11), USB cable |
| Manual | Yes |
Sustainability
| Sustainability certificates | ENERGY STAR |
Weight & dimensions
| Width | 112 mm |
| Depth | 380 mm |
| Height | 301 mm |
| Weight | 11.6 kg |
Packaging data
| Warranty card | Yes |
| Software CD | Yes |
| Bundled software | PowerChute Personal Edition |
| Package width | 238 mm |
| Package depth | 488 mm |
| Package height | 387 mm |
| Package weight | 13.2 kg |
Logistics data
| Products per pallet | 24 pc(s) |
| Harmonized System (HS) code | 85078000 |
| Products per master (outer) case | 1 pc(s) |
Other features
| Battery type | APCRBC124 |
| Nominal output voltage | 230 V |
| Nominal input voltage | 230 V |
| Networking features | 10/100/1000 Base-T |
| Packaging content | Qty 2- Detachable IEC Power Cord |
Description
The Back-UPS RS offers high performance protection for your business and office computer systems. It provides abundant battery backup power, allowing you to work through medium and extended length power outages. It also safeguards your equipment from damaging surges and spikes that travel along utility, phone and network lines. A distinguishing feature of the Back-UPS RS is automatic voltage regulation (AVR). AVR instantly adjusts both low and high voltages to safe levels, so you can work indefinitely during brownouts and overvoltage situations, saving the battery for power outages when you need it most. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and plentiful outlets (including transformer-block spaced outlets) make the Back-UPS RS the perfect unit to protect your business' productivity from the constant threat of power problems and lost data. Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. Audible alarms: Provide notification of changing flywheel conditions Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance Power-saving outlets: Automatically cuts power to idle equipment to conserve electricity. LCD display: Alpha-Numeric Display which displays system parameters and alarms. Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment Cold-start capable: Provides temporary battery power when the utility power is out. Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced. Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Audible alarms: Provides notification of changing utility power and UPS conditions. User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) USB connectivity: Provides management of the UPS via a USB port (not available on all models). Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles. Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery. Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging. Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit. Adjustable voltage sensitivity: Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications. Automatic Voltage Regulation (AVR): Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment. Battery fault detection: Monitors room and individual battery temperature changes for early detection of thermal runaway, shorted cells, open circuit, and bad battery. Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment. Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances. Audible alarms: Provides notification of changing utility power and UPS conditions. Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power. Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced. Battery replacement without tools: Allows quick, easy battery replacement. LED status indicators: Quickly understand unit and power status with visual indicators. Cold-start capable: Provides temporary battery power when the utility power is out. Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Resettable circuit breakers: Enables a quick recovery from overload events. Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles. User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Intelligent battery management: Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.
Condition: Refurbished
Free U.S. ground shipping
Typically 1–2 days handling, 3–7 days in transit.
Purchase orders accepted
Government, enterprise, data center and small business.
Buying 10+ units?
Get volume pricing and availability for BR1200GI.






