Home/Power Equipment/UPS/SUA3000XLT - APC Smart-UPS XL 2700W/3000VA 208V 5U...
SUA3000XLT - APC Smart-UPS XL 2700W/3000VA 208V 5U Tower/Rack Convertible UPS System

SUA3000XLT - APC Smart-UPS XL 2700W/3000VA 208V 5U Tower/Rack Convertible UPS System

SKU SUA3000XLT
APCShop all APC parts (559) ›
  • 3 kVA 2700 W
  • Sealed Lead Acid (VRLA)
  • Black
Available to order

SUA3000XLT isn't on our shelf today — we source it to order. Request a quote and we'll confirm price and lead time within one business day.

Key specifications

See full specs ↓
Output power capacity
3 kVA
Output power
2700 W
Input frequency
50/60 Hz
Surge energy rating
480 J
Emergency Power Off (EPO)
Yes
Noise level
53 dB

Product details

APC Smart-UPS XL 3000VA. Output power capacity: 3 kVA, Output power: 2700 W, Input frequency: 50/60 Hz. Battery technology: Sealed Lead Acid (VRLA), Typical backup time at full load: 5 min, Typical backup time at half load: 17 min. Product colour: Black, Cable length: 1.83 m. Certification: CSA,FCC Part 15 Class A,UL 1778. Weight: 62.3 kg

Specifications

Output power capacity
3 kVA
Output power
2700 W
Input frequency
50/60 Hz
Surge energy rating
480 J
Emergency Power Off (EPO)
Yes
Noise level
53 dB
Audible alarm(s)
Yes
Battery technology
Sealed Lead Acid (VRLA)
Typical backup time at full load
5 min
Typical backup time at half load
17 min
Battery recharge time
3 h
Cable length
1.83 m
Product colour
Black
LED indicators
Yes
Operating temperature (T-T)
0 - 40 °C
Storage temperature (T-T)
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m
Certification
CSA,FCC Part 15 Class A,UL 1778
Interface
DB-9 RS-232,SmartSlot
Output connections
(2) NEMA L6-20R (2) NEMA L6-30R
Input connection type
NEMA L6-20P
Dimensions (WxDxH)
196 x 503 x 432 mm
Nominal output voltage
208 V
Nominal input voltage
208 V

Description

SUA3000XLT Features -Plug-and-Play installation. -Rack/Tower convertible: Protects the initial investment in the UPS when migrating from tower to rack-mount environment. -Replace Battery LED: An external Replace Battery LED informs the end-user that the battery needs to be replaced. -USB connectivity: Provides management of the UPS via a USB port (not available on all models). Availability -Scalable runtime: Allows additional run time to be quickly added as needed. -Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery. -Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances. -Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature. -Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging. -Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power. -Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced. -Cold-start capable: Provides temporary battery power when the utility power is out. -Disconnected battery notification: Warns when a battery is not available to provide backup power. -Generator compatible: Ensures clean, uninterrupted power to protected equipment when generator power is used. Manageability -Network manageable: Provides remote management of the UPS over the network. -SmartSlot: Customize UPS capabilities with management cards. -Audible alarms: Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. -LED status indicators: Quickly understand unit and power status with visual indicators. -Disconnected battery notification: Warns when a battery is not available to provide backup power. -Serial Connectivity: Provides management of the UPS via a serial port. -InfraStruXure Manager compatible: Enables centralized management via the APC InfraStruXure® Manager. Serviceability -User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) -Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced -Predictive failure notification: Provides early-warning fault analysis ensuring proactive component replacement. -Resettable circuit breakers: Enables a quick recovery from overload events. Adaptability -Plug-and-Play external batteries: Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. -Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. -Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Condition: Refurbished

Free U.S. ground shipping

Typically 1–2 days handling, 3–7 days in transit.

Purchase orders accepted

Government, enterprise, data center and small business.

Warranty & RMA support

See warranty and returns.

Volume pricing

Buying 10+ units?

Get volume pricing and availability for SUA3000XLT.

Questions about this part?

Compatibility, condition, lead times — ask a specialist.

(888) 988-8093

Related products