SUA3000XLT - APC Smart-UPS XL 2700W/3000VA 208V 5U Tower/Rack Convertible UPS System
- 3 kVA 2700 W
- Sealed Lead Acid (VRLA)
- Black
SUA3000XLT isn't on our shelf today — we source it to order. Request a quote and we'll confirm price and lead time within one business day.
Key specifications
See full specs ↓- Output power capacity
- 3 kVA
- Output power
- 2700 W
- Input frequency
- 50/60 Hz
- Surge energy rating
- 480 J
- Emergency Power Off (EPO)
- Yes
- Noise level
- 53 dB
Product details
APC Smart-UPS XL 3000VA. Output power capacity: 3 kVA, Output power: 2700 W, Input frequency: 50/60 Hz. Battery technology: Sealed Lead Acid (VRLA), Typical backup time at full load: 5 min, Typical backup time at half load: 17 min. Product colour: Black, Cable length: 1.83 m. Certification: CSA,FCC Part 15 Class A,UL 1778. Weight: 62.3 kg
Specifications
- Output power capacity
- 3 kVA
- Output power
- 2700 W
- Input frequency
- 50/60 Hz
- Surge energy rating
- 480 J
- Emergency Power Off (EPO)
- Yes
- Noise level
- 53 dB
- Audible alarm(s)
- Yes
- Battery technology
- Sealed Lead Acid (VRLA)
- Typical backup time at full load
- 5 min
- Typical backup time at half load
- 17 min
- Battery recharge time
- 3 h
- Cable length
- 1.83 m
- Product colour
- Black
- LED indicators
- Yes
- Operating temperature (T-T)
- 0 - 40 °C
- Storage temperature (T-T)
- -15 - 45 °C
- Operating relative humidity (H-H)
- 0 - 95%
- Storage relative humidity (H-H)
- 0 - 95%
- Operating altitude
- 0 - 3000 m
- Non-operating altitude
- 0 - 15000 m
- Certification
- CSA,FCC Part 15 Class A,UL 1778
- Interface
- DB-9 RS-232,SmartSlot
- Output connections
- (2) NEMA L6-20R (2) NEMA L6-30R
- Input connection type
- NEMA L6-20P
- Dimensions (WxDxH)
- 196 x 503 x 432 mm
- Nominal output voltage
- 208 V
- Nominal input voltage
- 208 V
Description
SUA3000XLT Features -Plug-and-Play installation. -Rack/Tower convertible: Protects the initial investment in the UPS when migrating from tower to rack-mount environment. -Replace Battery LED: An external Replace Battery LED informs the end-user that the battery needs to be replaced. -USB connectivity: Provides management of the UPS via a USB port (not available on all models). Availability -Scalable runtime: Allows additional run time to be quickly added as needed. -Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery. -Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances. -Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature. -Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging. -Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power. -Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced. -Cold-start capable: Provides temporary battery power when the utility power is out. -Disconnected battery notification: Warns when a battery is not available to provide backup power. -Generator compatible: Ensures clean, uninterrupted power to protected equipment when generator power is used. Manageability -Network manageable: Provides remote management of the UPS over the network. -SmartSlot: Customize UPS capabilities with management cards. -Audible alarms: Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. -LED status indicators: Quickly understand unit and power status with visual indicators. -Disconnected battery notification: Warns when a battery is not available to provide backup power. -Serial Connectivity: Provides management of the UPS via a serial port. -InfraStruXure Manager compatible: Enables centralized management via the APC InfraStruXure® Manager. Serviceability -User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) -Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced -Predictive failure notification: Provides early-warning fault analysis ensuring proactive component replacement. -Resettable circuit breakers: Enables a quick recovery from overload events. Adaptability -Plug-and-Play external batteries: Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. -Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. -Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Condition: Refurbished
Free U.S. ground shipping
Typically 1–2 days handling, 3–7 days in transit.
Purchase orders accepted
Government, enterprise, data center and small business.
Buying 10+ units?