Key specifications

See full specs ↓
Output power capacity
3 kVA
Output power
2700 W
Waveform
Sine
Input operation voltage (min)
70 V
Input operation voltage (max)
153 V
Input frequency
50/60 Hz

Product details

APC SMX3000LVNC. Output power capacity: 3 kVA, Output power: 2700 W, Waveform: Sine. AC outlet types: NEMA 5–15R, NEMA 5–20R, NEMA L5-30R, Power plug: NEMA 5-30P, AC outlets quantity: 7 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Battery recharge time: 3 h. Form factor: Rackmount/Tower, Product colour: Black, Rack capacity: 2U. Compliance certificates: RoHS, Certification: BSMI, CSA, EN 50091-2, EN 55022 Class A, FCC Part 15 Class A, NOM, TUV, UL 1778, VCCI Class A REACH

Specifications

Output power capacity
3 kVA
Output power
2700 W
Waveform
Sine
Input operation voltage (min)
70 V
Input operation voltage (max)
153 V
Input frequency
50/60 Hz
Surge energy rating
540 J
Efficiency
97.5%
Emergency Power Off (EPO)
Yes
Output voltage Total Harmonic Distortion (THD)
5%
Noise level
55 dB
Audible alarm(s)
Yes
AC outlet types
NEMA 5–15R, NEMA 5–20R, NEMA L5-30R
Power plug
NEMA 5-30P
AC outlets quantity
7 AC outlet(s)
USB 2.0 ports quantity
1
Battery technology
Sealed Lead Acid (VRLA)
Number of batteries supported
1
Battery recharge time
3 h
Form factor
Rackmount/Tower
Rack capacity
2U
Cable length
2.44 m
Product colour
Black
Display type
LED
LED indicators
Yes
Operating temperature (T-T)
0 - 40 °C
Storage temperature (T-T)
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m
Compliance certificates
RoHS
Certification
BSMI, CSA, EN 50091-2, EN 55022 Class A, FCC Part 15 Class A, NOM, TUV, UL 1778, VCCI Class A REACH
Width
178 mm
Depth
483 mm
Height
432 mm
Package weight
47.7 kg
Package dimensions (WxDxH)
586 x 633 x 330 mm

Description

Intuitive LCD interface Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. High frequency design Reduces or eliminates bulky transformers resulting in lighter units for ease of handling. Auto recognition of external batteries UPS recognizes when external battery packs are attached and automatically adjusts runtime. Predictive replace battery date Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. Energy meter Provides actual kilowatt hours of usage for energy conscious users. Outlet group control Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups). Load shedding Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups). Pure sine wave output on battery Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics. Multiple switched outlet groups Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. Wide input voltage range Designed for harsh electrical environments to save battery life. StruxureWare Central compatible Enables centralized management via StruxureWare Central. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance High online efficiency Reduces utlility costs, generates less heat. LED Indicators Provide easy-to-read status of the unit and utility power conditions. Overload protection Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload. SmartSlot Customize UPS capabilities with management cards. Cold-start capable Provides temporary battery power when the utility power is out. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Disconnected battery notification Warns when a battery is not available to provide backup power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Audible alarms Provides notification of changing utility power and UPS power conditions User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) USB connectivity Provides management of the UPS via a USB port (not available on all models). Serial Connectivity Provides management of the UPS via a serial port. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). Scalable runtime Allows additional run time to be quickly added as needed. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Network manageable Provides remote power management of the UPS over the network. Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. Predicitive failure notification Provides early-warning fault analysis ensuring proactive component replacement. Sequenced network shutdown and reboot Customize network shutdown and reboot sequence of connected servers and UPSs.

Condition: Refurbished

Free U.S. ground shipping

Typically 1–2 days handling, 3–7 days in transit.

Purchase orders accepted

Government, enterprise, data center and small business.

Warranty & RMA support

See warranty and returns.

Volume pricing

Buying 10+ units?

Get volume pricing and availability for SMX3000LVNC.

Questions about this part?

Compatibility, condition, lead times — ask a specialist.

(888) 988-8093

Related products

Loading related inventory…